round bar. At access points, pipes substituted by short link galvanised chain with hook and eyes.
6.11 ·ç»úVENTILATORS
»ú²ÕÉèÖÃÁ½Ì¨×ã¹»ÈÝÁ¿µÄÖáÁ÷·ç»ú£¬ÆäÖÐÓÐ1̨¿ÉÄæ×ª¡£¹©·çÖÁ»ú²ÕµÄÖ÷·çµÀÓɺñΪ1.2mm¶ÆÐ¿°×ÌúÆ¤ÖÆ³É£¬Ö§·çµÀÓɺñΪ0.75mm¶ÆÐ¿°×ÌúÆ¤ÖÆ³É£¬ÉÏÃæ°²×°·çÕ¤¡£îÂÏ´¼äºÍ³ø·¿°²×°ÖáÁ÷³é·ç»ú¡£
Two (2) fans of adequate capacity are to be provided for ventilation of engine room, one of which is axial flow. Ventilation duct will provide ventilation to the engine room main trunking made of 1.2mm thick galvanized sheet metal, distribution trunking made of 0.75mm thick
galvanized sheet metal c/w louver opening. Washplace, galley is to be provided with axial flow extractor fans.
6.12 ¼×°åÉ豸ÕÖ×ÓCOVERS FOR DECK EQUIPMENT
°²×°ÔÚ¼×°åµÄÉ豸Èç´«Éù¹Ü¡¢ÂÞ¾¡¢Ì½Õյơ¢Ãª»ú¡¢ÍÏÒ·½Ê³µµÈ¶¼ÒªÅäÓÐÔúʵµÄ·«²¼ÕÖ×Ó¡£ Strong canvas covers for deck equipment such as voice pipe, compass, searchlights, windlass, towing winch etc are to be provided.
6.13 Â¥ÌÝLADDERS
ËùÓÐÂ¥ÌÝΪ¸ÖÖÆµÄ¡£ÊÒÍâÂ¥ÌÝÒª·À»¬£¬ÓɶÆÐ¿»¨¸Ö°åÖÆ³É»òÀàËÆ½á¹¹¡£º¸×°ÔÚ²Õ±ÚÉϵÄÖ±Ìݵıâ¸Ö̤²½Ó¦¾àÀë²Õ±Ú250mm¡£
All ladders are to be of steel construction. External ladders to be antislip and made of galvanized chequered plate or similar construction. Vertical ladder to be constructed with square bar rungs welded to steel flat bar and to be clear of steel bulkheads.
£¨1£©ÊÒÍâÂ¥ÌÝÉÏ϶˲ÉÓöÆÐ¿ÂÝ˨¹Ì¶¨£¬²¢ÇÒ¿ÉÒÔ²ðÒÆ¡£
Upper and lower ends of outside ladders should be secured by galvanized studs, and can be moved.
£¨2£©Â¥ÌÝ×î´óб¶ÈΪ60o¡£Maximum degree of inclination of ladder is: 60o
6.14 ÍÏÒ··À»¤×®TOWING BOLLARDS
Á½Ì×Ö±¾¶12¡±£¬Ê®×ÖÐÍÇÒÓɺñ±Ú¹ÜÖÆ³ÉµÄÍÏÒ·×®°´Í¼²¼ÖÃÔÚ´¬ô¼ôº¡£
Two (2) 12¡¯¡¯ dia. NB heavy pipe cross towing bollards are to be fitted on fore and aft main deck.
6.15 Ͷ¹âµÆFLOODLIGHTS
4 x 500W ¸ßÑ¹ÄÆµÆ£¬ô¼ôº¸÷1Ö»£¬´¬ô±2Ö»¡£
4 x 500W high pressure sodium lamp, forward and aft each one, two (2)on Shipcenter.
6.17 ̽Õյƣ¨°²×°Î»ÖÃÓÉ´¬¶«¾ö¶¨£©SEARCHLIGHTS (The installing locations to be decided by The Buyer)
- 25 -
2 x 1000W£¬ÔÚ¼ÝÊ»ÊÒÄÚÊÖ¶¯¿ØÖÆ£¬1Ö»¹¯ë¯µÆ£¬1ֻΪ°×³ãµÆ¡£
2 x 1000W, manual control on wheelhouse, one (1) is mercury xenon lamp, one (1) is incandescence lamp.
6.18 ϵÀÂ×®MOORING BOLLARDS
a£©´øÀÂ×®BOLLARDS Èç×ÜͼËùʾ²¼ÖÃ6Ö»8¡±´¬Óúñ±Ú¹ÜÖÆ³ÉµÄË«Öù´øÀÂ×®¡£
Six (6) 8¡¯¡¯ dia. NB heavy pipe double bollards are to be fitted as shown on the drawings.
b£©µ¼À¿×FAIRLEADS ÈçͼËùʾÔÚ´¬ô¼ÏÏǽ²¼ÖÃÖ»µ¼À¿ף¬ô¼²¿4Ö»£¬ôº²¿2Ö»¡£4 pieces for forward and 2 pieces for afterward.
Four (4) fairleads are to be fitted on forward bulwark as shown on the drawings.
6.19 êÁ´Í² & êѨHAWSE PIPES & ANCHOR RECESSES
Á½Ö»10¡± ´¬ÓÃSch. 80êÁ´Í²Óë14mm´¬¿Ç°åº¸×°¡£
Two (2) 10¡¯¡¯ dia. NB, Sch 80 hawse pipes welded to 14mm hull anchor recesses.
6.20 ÍÏÒ·½Ê³µTOWING WINCH
һ̨µçҺʽ½Ê³µ°²×°ÔÚÖ÷¼×°åÉÏ¡£½Ê³µÈÝÁ¿ºÍÅäÖüûÈçÏ£º
One (1) towing winch is to be driven by electric-hydraulic, which to be fitted on main deck. The capacity and parameters as followings:
ÐÍʽTYPE£º Ë«¹öͲ¡¢Ë«ÏµÀ¾íͲ double drums, double gypsies
¹öͲÈÝÁ¿Drum Capacity£º Âú×ãÖ±¾¶47.5mm¡Á700m³¤µÄ¸ÖÀ 700m of mm dia. SWR 47.5mm x 700m ÀëºÏÆ÷Clutch£º µç´Åʽelectromagnetic ¿ØÖÆControl£º »úÅԺͼÝÊ»ÊÒÒ£¿Øremote in W/H & local at site ÉþËÙRated Pull£º 10¶Ö ¡Á 6m/min 10t ¡Á 6m/min ÍÏÁ¦Pull£º 40¶Ö 40T
ÍÏÒ·½Ê³µÓ¦ÄÜ´Ó¼ÝÊ»ÊÒÒ£¿ØºÍ¾ÍµØ¿ØÖÆ¡£»úÅÔ¿ØÖÆÏä°²×°ÔÚ¶Ìì¼×°å£¬ÆäÍâÓ¦Éè´ø¸Ç×ÓÌúÏä×Ó£¬ÒÔ·À±»·çÀËË𻵡£
Towing winch can be controlled remote in wheelhouse and local at site. Control box aside the winch should be fitted on exposed deck, and setup with steel box with cover against damage from storm.
µÚÆß½Ú °²È« & º½ÐÐÉ豸
SECTION 7 - SAFETY & NAVIGATION EQUIPMENT
7.0 ¾ÈÉúÉ豸LIFT SAVING EQUIPMENT
- 26 -
¾ÈÉúÉ豸ӦÍêÈ«Âú×ãÉÌ´¬£¨·Ç³£¹æ´¬£©SOLAS°²È«¹æ·¶ÒÔ¼°ÅäÔ±14ÈËÏà¹ØÐ޸ݸҪÇó¡£ Life saving equipment is to be in accordance with the requirements of the Government authority for the intended trade & Solas 1974 of Merchant Shipping£¨Non convention vessel£© for a complement of 14 men.
1£©¾ÈÉú·¤LIFERAFTS
2Ö»15ÈËÆøÕÍʽ¡¢²£Á§¸ÖÍâ¿Ç´ø¾È¼±°ü¾ÈÉú·¤£¬Âú×ãSOLAS 74¹«Ô¼¡£¾ÈÉú·¤´¢·ÅÔÚÉý¸ß¼×°å½ÂÁ´Ê½Ö§¼ÜÉÏ£¬¿ÉÒÔ¿ìËÙÊ©·ÅÏÂË®¡£
Two (2) 15-man inflatable liferafts with full emergency pack in rigid fibre glass container conforming to SOLAS 74 convention. The liferafts are to be stowed on the raised deck in hinged type cradles for quick sideway launching.
2£©¾ÈÉúȦLIFEBUOYS
×ܹ²8Ö»¾ÈÉúȦÅäÖã¬Ó¦Âú×ã¹æ·¶ÒªÇó£º
Total eight (8) lifebuoys to be supplied in accordance with rules: ? 4Ö»´ø30Ã׳¤¾ÈÉúÉþ
Four (4) lifebuoys with 30m buoyancy line ? 4Ö»×ÔȼµÆ£¨ÆäÖÐ2Ö»ÄÜ·¢ÉäÑÌÐźţ©
Four (4) self-igniting electric lights, two (2) lifebuoys with s smoke signals.
3£©¾ÈÉúÒ´ø¿ÚÉں͵ÆLIFEJACKETS with whistles and lights
20Ì×ÐÍʽÈϿɵľÈÉúÒ£¬Ã¿¸ö´²¸½½ü°²·ÅÒ»Ö»¡£
Twenty (20) approved type lifejackets are to be supplied and stowed adjacent to each berth.
4£©Ðźŵ¯PYROTECHNICS
? Ò»Ì×ÉþÅ×ʽװÖã¨ÅäÓÐ4Ö»É䵯£¬4¸ùÉþ£©
One (1) line throwing apparatus (with 4 projectiles, 4 lines) ? 12Ö»½µÂäÉ¡»ð¼ý
Twelve (12) parachute distress rockets
? 2Ö»·ÀË®³ÈÉ«ÑÌÎíÐźŵ¯£¬Ã¿Ö»ÄܳÖÐøÊÍ·Å120Ãë
Two (2) orange smoke signals each to have 120 seconds discharge time and be waterproof.
5£©·µ¹â´øRETRO-REFLECTIVE TAPE
¾ÈÉúÉ豸ÉÏÓ¦Ìù·µ¹â´ø¡£
To be fitted to all lifesaving appliances
7.1 Ïû·ÀÉ豸FIRE-FIGHTING EQUIPMENT
Ïû·ÀÉ豸ӦÂú×ã´¬¼¶Éç¼°Õþ¸®¹æ·¶ÒªÇ󣬲¢ÇÒ»¹ÒªÂú×ãÏÂÁÐÒªÇó£º
Fire-fighting equipment is to be provided to meet classification, government regulations and generally in accordance with the following:
- 27 -
1£©Ïû·À×ܹÜFIRE MAIN
°²×°1¸ùÏû·À×ܹܺÍ5Ö»11/2¡±ÇàÍÏû·À˨£¬¼ÝÊ»¼×°å1Ö»£¬Ö÷¼×°å2Ö»£¬»ú²Õ2Ö»¡£Ã¿Ö»Ïû·À˨¸½½ü°²×°1ֻˮÁú´øÏ䣬ÏäÄÚ·Å15mÅäÓлÆÍ½Ó¿ÚºÍÅç×ìµÄ·«²¼Ïû·ÀÈí¹Ü¡£
A fire main and five (5) 11/2¡± bronze hydrants are to be fitted, one (1) on wheelhouse deck, two (2) on main deck and two (2) in engine room. 15m canvas fire hose c/w brass coupling and nozzle is to be supplied and stowed alongside each hydrant in a protective box.
2£©Ïû·ÀÈËÔ±×°±¸FIREMAN'S OUTFITS
ÌṩһÕûÌ×Ïû·ÀÈËÔ±×°±¸£º
One (1) complete set of fireman's outfit are to be provided: a£©Ò»Ì×·À»¤·þOne (1) protective clothing
b£©Ò»Ì׺ôÎüÆ÷¼°°²È«Éþ One (1) breathing apparatus and safety line c£©Ò»Ö»Ì«Æ½¸« one (1) fireman¡¯s axe
d£©Ò»Ö»±ãЯÐîµç³ØÊ½°²È«µÆ One(1) safety lamp of portable battery type e£©Ò»¸±ÊÖÌ׺Íһ˫ѥ×Ó One(1) set of gloves and boots f £©Ò»Ö»Ñ¹Á¦²âÁ¿¼Æ One£¨1£©pressure gauge tester
3£©±ãЯʽÃð»ðÆ÷ PORTABLE FIRE EXTINGUISHERS
Ãð»ðÆ÷µÄ¹©Ó¦¾ùÓ¦Âú×ã´¬¼¶Éç/Õþ¸®µ±¾ÖµÄÒªÇó¡£ÏÂÁÐÅäÖÃÒÔ¹©²Î¿¼£¨Ó¦·ûºÏ×îÖÕÈϿɣ©£º Fire extinguishers as required by the classification/government authority are to be supplied and installed. For guidance, they are as followings: (subject to final approval)
ÊýÁ¿
µØµãPOSITION ÐÎʽTYPE
NO. 2 ¼×°å¾Óס²ÕÊÒ Deck accommodation 9ÉýҺ̬CO2 9 liters water CO2 1 ¼×°å´¢²ØÊÒ Deck store room 9ÉýÅÝÄ 9 liters foam 1 »ú²Õ½ø¿Ú Engine room entrance 9ÉýÅÝÄ 9 liters foam
¼×°åÏ´¬Ô±¾Óס²ÕÊÒ 9ÉýҺ̬CO2
1
under deck crew¡¯s cabins 9 liters water CO2
45ÉýÅÝÄ ¨C »úе
»ú²Õ Engine room 10
45 liters foam-mechanical
9ÉýÅÝÄ 9 liters foam
4£©Ó¦¼±Ïû·À±ÃEMERGENCY FIRE PUMP
´¬ÉÏÓ¦Å䱸һ̨ÈÝÁ¿Îª25m3/hºÍѹͷ25mµÄ±ãЯʽ²ñÓÍ»úÇý¶¯Ó¦¼±Ïû·À±Ã¡£
One (1) portable diesel engine driven emergency fire pump of capacity 25m3/h at 25m head.
7.2 µ¼º½É豸£¨½ø¿Ú£©NAVIGATION EQUIPMENT (IMPORT)
- 28 -