OTN±ê×¼¼ò½éV1.0
1114 15¹«¿ª¡ø£¨±£ÃÜÆÚ£©
3824Frame i2341BIP8OPUkBIP8Frame i+12341BIP8BIP8Frame i+2234G.709/Y.1331_F15-15ͼ12 PM-BIP8µÄ¼ÆË㷶ΧºÍ·ÅÖÃλÖà PM-BDI£¬È«³ÆÎªODUk PM backward defect indication£¬Ö»ÓÐһλ£¬Î»ÖÃΪ×Ö½Ú£¨3£¬12£©µÄλ5¡£¶¨ÒåºÍSM-BDI»ù±¾Ò»Ö£¬ÓÃÀ´ÏòÉÏÓη´Ïò·¢ËÍ·¾¶¼ì²âʱÓöµ½µÄʧЧÐÅÏ¢£¬1ָʾÓÐODUkʧЧ£¬0ΪÕý³£¡£ PM-BEI£¬È«³ÆÎªODUk PM backward error indication£¬¹²4λ£¬Î»ÖÃΪ×Ö½Ú£¨3£¬12£©µÄλ1ÖÁλ4¡£¶¨ÒåºÍSM-BDI»ù±¾Ò»ÖÂ(µ«Ã»ÓÐSM-BIAE)£¬ÓÃÀ´ÏòÉÏÓη´Ïò·¢Ëͱ¾½ÚµãµÄPM-BIP8µÄÎóÂë¸öÊý£¬ÎóÂ뷶ΧΪ0£8¡£×¢ÒâSM-BEI×ֶΰüº¬ÁËÁ½ÖÖÐÅÏ¢BEIºÍBIAE£¬Òò´ËÈ«³ÆÊÇSM-BEI/IAE¡£µ«ÊÇPM-BEIûÓÐBIAEÐÅÏ¢¡£ÓÉÓÚPM-BEI¹²ÓÐ4룬µ«¿ÉÄÜ´æÔڵĴíÎóÊýÖ»ÓÐ0£8£¬ËùÒÔȡֵ9£15Ϊ·Ç·¨Öµ£¬Ó¦¸ÃÈÏΪ´ËʱÎóÂëΪ0£¬Èç±í4Ëùʾ¡£ ±í4 PM-BEIȡֵ¶¨Òå ODUk PM BEI bits 1 2 3 4 0 0 0 0 0 0 0 1 0 0 1 0 0 0 1 1 0 1 0 0 0 1 0 1 0 1 1 0 0 1 1 1 1 0 0 0 1 0 0 1 to 1 1 1 1 BIP violations 0 1 2 3 4 5 6 7 8 0 PM-STAT£¬È«³ÆÎªODUk PM status £¬¹²3λ£¬Î»ÖÃΪ×Ö½Ú£¨3£¬12£©µÄλ6ÖÁλ8¡£´Ë×Ö¶ÎÓÃÀ´Ö¸Ê¾µ±Ç°µÄά»¤Ðźţ¨Maintenance Signal£©£¬Èç±í5Ëùʾ¡£
±í5 ODUk PM-STATµÄ¶¨Òå
±¾ÎÄÖеÄËùÓÐÐÅÏ¢¹éÖÐÐËͨѶ¹É·ÝÓÐÏÞ¹«Ë¾ËùÓУ¬Î´¾ÔÊÐí£¬²»µÃÍâ´« µÚ 15 / 41 Ò³
OTN±ê×¼¼ò½éV1.0
¹«¿ª¡ø£¨±£ÃÜÆÚ£©
Status PM byte 3 bits 6 7 8 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 Normal path signal Reserved for future international standardization Reserved for future international standardization Reserved for future international standardization Reserved for future international standardization Maintenance signal: ODUk-LCK Maintenance signal: ODUk-OCI Maintenance signal: ODUk-AIS Ëùνά»¤ÐźÅÖ÷ÒªÊÇÖ¸µ±ÒµÎñ²»Õý³£Ê±£¬Í¨¹ýijЩ¿ªÏúÈ¡ÌØÊâÖµ»òÕß·¢ËÍÌØÊâÂëÐÍ֪ͨÏÂÓεĽÓÊÕÉ豸µ±Ç°±¾½ÚµãµÄ״̬¡£ÀýÈçSDHµÄMS-AIS¼´Ï൱ÓÚÒ»ÖÖά»¤ÐÅÏ¢£¬µ±SDHÉ豸·¢ÏÖ½ÓÊÕʧЧʱ£¬½«ÏòÏÂÓη¢ËÍMS-AIS£¬´Ëʱ³ýRSOH(¶Î¿ªÏúµÄǰÈýÐÐ)ÍâËùÓÐ×Ö½Ú£¨°üÀ¨SOHºÍ¾»ºÉ£©È«²¿Îª1¡£¶ÔÓÚOTNÀ´Ëµ£¬Î¬»¤ÐźŸü¼Ó¸´ÔÓ£¬OTUk²ãºÍODUk²ãµÈ¶¼ÓÐ×Ô¼ºµÄά»¤Ðźţ¬ÀýÈçOTUk-AISºÍODUk-AIS¡£ºóÃæµÄά»¤ÐźŲ¿·Ö½«×÷Ïêϸ½éÉÜ¡£ PM-STAT¾ÍÊÇÓÃÀ´Ö¸Ê¾µ±Ç°ODUkÖ¡´¦ÓÚÄÄÖÖά»¤ÐźÅ״̬¡£µ±ÒµÎñÕý³£Ê±È¡ÖµÎª001¡£ µ±´¦ÓÚά»¤ÐźÅ״̬ʱ£¨ODUk-AIS,ODUk-OCI,ODUk-LCK£©£¬³ý¹ýPM-STAT¿ªÏúÒÔÍâµÄËùÓÐPM¿ªÏú½«»áÒÔÒ»ÖÖÌØÊâµÄ¸ñʽ³öÏÖ£¨È«1£¬0110 0110 »òÕß 0101 0101²»¶ÏÖØ¸´£©¡£ 5.2.2 ODUkµÄTCM¿ªÏú TCMµÄÈ«³ÆÎªTandem Connection Monitoring¡£ÔÚODUkÖ¡ÖУ¬TCM¿ªÏú¹²ÓÐ6×飬λÓÚODUk¿ªÏúÇøÓòÄÚ£¬°üÀ¨Á½²¿·Ö£¬Ò»²¿·ÖÔÚµÚ¶þÐÐÖеÄ×Ö½Ú£¨2£¬5£©ÖÁ×Ö½Ú(2£¬13)£»Ò»²¿·ÖÔÚµÚÈýÐÐÖеÄ×Ö½Ú£¨3£¬1£©ÖÁ×Ö½Ú(3£¬9)¡£ TCMÓÃÓÚ¼ì²âODUkµÄ¸÷ÖÖÁ¬½ÓÇé¿ö¡£TCM1-6µÄÏêϸÓÃ;ûÓж¨Ò壬Óû§¿ÉÒÔ×Ô¼º¾ö¶¨Ê¹Óü¸×éTCMºÍ¾ö¶¨¸÷¸öTCM¼à¿ØµÄÁ¬½ÓµÄÏêϸλÖá£ÀýÈçÏÂÃæÊÇʹÓÃTCMµÄÒ»¸öÀý×Ó¡£ ±¾ÎÄÖеÄËùÓÐÐÅÏ¢¹éÖÐÐËͨѶ¹É·ÝÓÐÏÞ¹«Ë¾ËùÓУ¬Î´¾ÔÊÐí£¬²»µÃÍâ´« µÚ 16 / 41 Ò³
OTN±ê×¼¼ò½éV1.0
TCM6TCM5TCM4TCM3TCM2TCM1TCM6TCM5TCM4TCM3TCM2TCM1TCM6TCM5TCM4TCM3TCM2TCM1TCM6TCM5TCM4TCM3TCM2TCM1TCM6TCM5TCM4TCM3TCM2TCM1¹«¿ª¡ø£¨±£ÃÜÆÚ£©
TCM6TCM5TCM4TCM3TCM2TCM1TCM6TCM5TCM4TCM3TCM2TCM1A1B1C1C2B2B3B4A2C1-C2B1-B2B3-B4A1-A2TCMiTCMiTCM OH field not in useTCM OH field in useG.709/Y.1331_F15-16ͼ13 ǶÈëºÍ¼¶ÁªÐ͵ÄODUkÁ¬½Ó¼ì²â ÔÚÉÏͼÖУ¬ODUkͨ¹ýÁ˶à²ã½ÚµãµÄ´¦Àí£¬TCMi£¨i=1,6£©¿ÉÓÃÀ´¼ì²â²ãÓë²ãÖ®¼äµÄÁ¬½ÓÇé¿ö¡£TCM1ÓÃÓÚA1ÖÁA2½ÚµãÖ®¼äµÄÁ¬½Ó¼ì²â£¬TCM2ÓÃÓÚ×Ó²ãB1-B2ºÍB3-B4Ö®¼äµÄÁ¬½Ó¼ì²â£¬TCM3ÓÃÓÚ×Ó²ãC1-C2Ö®¼äµÄÁ¬½Ó¼ì²â¡£ÔÚÉÏͼÖУ¬A1-A2/B1-B2/C1-C2 ºÍ A1-A2/B3-B4¶¼ÊÇǶÈë¹ØÏµ£¬ B1-B2/B3-B4ÊǼ¶Áª¹ØÏµ¡£ TCMiÒ²¿ÉÓÃÓÚ¸²¸ÇÐεÄOTUkÁ¬½Ó¼ì²â£¬Èçͼ14Ëùʾ¡£ TCM6TCM5TCM4TCM3TCM2TCM1TCM6TCM5TCM4TCM3TCM2TCM1TCM6TCM5TCM4TCM3TCM2TCM1TCM6TCM5TCM4TCM3TCM2TCM1TCM6TCM5TCM4TCM3TCM2TCM1A1B1C1B2C2A2C1-C2B1-B2A1-A2TCMiTCMiTCM OH field not in useTCM OH field in useG.709/Y.1331_F15-17
ͼ14 ¸²¸ÇÐ͵ÄODUkÁ¬½Ó¼ì²â
ÉÏͼÖУ¬B1-B2²ãʹÓÃTCM2×÷ΪÁ¬½Ó¼ì²â£¬C1-C3ʹÓÃTCM3×÷ΪÁ¬½Ó¼ì²â£¬µ«B1-B2
±¾ÎÄÖеÄËùÓÐÐÅÏ¢¹éÖÐÐËͨѶ¹É·ÝÓÐÏÞ¹«Ë¾ËùÓУ¬Î´¾ÔÊÐí£¬²»µÃÍâ´« µÚ 17 / 41 Ò³
OTN±ê×¼¼ò½éV1.0
ºÍC1-C2Ö®¼äÓÐÒ»²¿·ÖÊÇÖØµþµÄ£¬ËûÃÇÖ®¼äÏ໥¸²¸Ç¡£
¹«¿ª¡ø£¨±£ÃÜÆÚ£©
×ÛÉÏËùÊö£¬µ±ODUkÖ¡¾¹ý¶à¸ö½Úµãʱ£¬ÎÒÃÇ¿ÉÒÔ¶¨ÒåijЩ½ÚµãÖ®¼ä´æÔÚÁ¬½Ó¹ØÏµ£¬²¢Ê¹ÓÃTCMiÀ´¼ì²âºÍ¹ÜÀíÕâЩÁ¬½Ó¹ØÏµ¡£
ÿ¸öODUk-TCMiµÄ½á¹¹ÍêȫһÑù£¬¶¼ÊÇ3¸ö×Ö½Ú£¬°üÀ¨Èçϲ¿·Ö£º
? ? ? ? ?
trail trace identifier (TTI); bit interleaved parity 8 (BIP-8); backward defect indication (BDI);
backward error indication and backward incoming alignment error (BEI/BIAE); status bits indicating the presence of TCM overhead, incoming alignment error, or a maintenance signal (STAT). ÏÔÈ»TCMi¿ªÏúºÍPM¿ªÏú»ù±¾Ò»Ñù£¬Î¨Ò»²»Í¬µÄµØ·½¾ÍÊÇTCM-BEI/BIAEºÍPM-BEI¡£TCM-BEIÕÕ°áSM-BEIÖе͍Ò壬¾ßÓÐBIAE¡£Êµ¼ÊÉÏÔÚÔÀ´µÄG.709±ê×¼ÖУ¨°æ±¾V1.0,V2.0£©TCM-BEIµÄ¶¨ÒåºÍPM-BEIÍêȫһÖ£¬Ã»ÓÐBIAEµÄȡֵ£¬µ«ÊÇÔÚ×îеÄV2.1ÖÐÔö¼ÓÁËBIAEµÄ¶¨Òå¡£
ODUk-TCMiµÄ¿ªÏú½á¹¹Èçͼ15Ëùʾ¡£ TCMi1TTIi2BIP-8i30SAPI1516DAPI313212345BDIi678BEIi/BIAEiSTATiG.709/Y.1331_F15-14Operatorspecific63 ͼ15 ODUk-TCMiµÄ¿ªÏú½á¹¹
TCMi-TTI£¬È«³ÆÎªODUk TCM trail trace identifier (TTI)£¬Ã¿×éTCMiÖ㤶ÈΪһ¸ö×Ö½Ú¡£´Ë×Ö¶ÎÓÃÓÚ´«ËÍTCM¶Î(tandem connection monitoring)µÄTTIÐÅÏ¢£¬ÓÉÁ¬Ðø64Ö¡ÖеĴ˿ªÏú×é³É64×Ö½ÚµÄÐÅÏ¢£¬¶¨ÒåͬSM-TTIÍêȫһÖ¡£´Ë64×Ö½ÚTTIÐÅÏ¢ÔÚOTUk¸´Ö¡ÖÐµÄ¶ÔÆë·½Ê½Ò²ºÍSM-TTIÍêȫһÑù£¬µÚÒ»×Ö½Ú·Ö±ð¶ÔÓ¦ÓÚ¸´Ö¡0£¬0x40,0x80,0xc0¡£
TCM-BIP-8£¬È«³ÆÎªODUk TCM error detection code (BIP-8)£¬Ã¿×éTCMiÖ㤶ÈΪһ¸ö×Ö½Ú¡£´Ë¿ªÏúΪBIP-8УÑéÐÅÏ¢£¬½á¹¹ºÍ¶¨ÒåͬPM-BIP-8ÍêȫһÑù£¬µ«ÓÃÓÚTCM¼à²â£¬¼ÆË㷶ΧҲÊÇÕû¸öOPUkÖ¡£¨µÚ15Áе½µÚ3824ÁУ¬OPUkÖ¡µÄ½á¹¹¼û4.5£©£¬´¦Àí·½Ê½Ò²Ò»Ñù£¬µÚiÖ¡µÄBIP-8УÑé½á¹û·Åµ½µÚi£«2Ö¡µÄTCMi-BIP8¿ªÏúλÖÃÉÏ¡£
TCM-BDI£¬È«³ÆÎªODUk TCM backward defect indication£¬Ö»ÓÐһ룬¶¨ÒåºÍPM-BDIÒ»Ö£¬ÓÃÀ´ÏòÉÏÓη´Ïò·¢ËÍ·¾¶¼ì²âʱÓöµ½µÄʧЧÐÅÏ¢£¬1ָʾÓÐODUkʧЧ£¬0ΪÕý³£¡£
TCM-BEI/BIAE£¬È«³ÆÎªODUk TCM backward error indication (BEI) and backward ±¾ÎÄÖеÄËùÓÐÐÅÏ¢¹éÖÐÐËͨѶ¹É·ÝÓÐÏÞ¹«Ë¾ËùÓУ¬Î´¾ÔÊÐí£¬²»µÃÍâ´« µÚ 18 / 41 Ò³